Notifier Fire Alarms – RP-2001

Beautifully suited for all your web-based needs

Notifier Fire Alarms – RP-2001

In stock N/A .

The RP-2001 is a six-zone FACP for single and dual hazard deluge and preaction applications. The RP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The RP-2001 is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The RP-2001 supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The RP-2001E offers the same features as the RP-2001 but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and 240 VAC versions of the panels.

Listed to UL Standard 864, 9th edition.
• FM Approved.
• Designed for sprinkler standards NFPA 13, 15 and 16.
• Dual hazard operation.
• Adjustable waterflow discharge timer and two soak timers.
• Cross-zone (double-interlock) capability.
• Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
• System Sensor i3 series detectors compatible.
• Four programmable Style Y (Class B) output circuits – (special application power).
• Strobe Synchronization: – System Sensor – Wheelock – Gentex – Faraday – Amseco
• Three programmable Form-C relays.
• 7.0 amps total 24 VDC output current.
• Resettable and non-resettable output power.

Initiating Device Circuits 6 Class B
Output Circuits 4 Class B; rated at 3 amp
Discharge Timer Yes, Programmable
Soak Timer Yes:
Cross Zone/Interlock Yes
Annunciators Yes; up to 8 LCD
Dispaly 80 Character LCD
Power 7.0 amps total system power